Generator/ Transmitter: Searching for an Induced Signal
The search pattern used to find the Generator/ Transmitter
signal when applied by Induction Mode is slightly different
to the search pattern used on other modes.
1. Move AT LEAST 10 metres away from the Generator/
Transmitter position with your Locator. This is to avoid the
Locator picking up the airborne signal rather than the signal
induced onto the buried service.
2. Stand so that you are roughly in line with the end of
the Generator/ Transmitter and hold the Locator so that
the side of the Locator is facing towards the Generator/
Transmitter.
3. Select Generator Mode or Transmitter Mode.
(The MXL Locator must be set to the same frequency as the
MXT Transmitter).
4. Adjust the sensitivity so that the Locator is JUST showing
a visual response and emitting an audible response.
NOTE A Generator/ Transmitter will transmit a significant amount of signal into the air as well as into the ground.
Make sure you keep the Locator upright at all times to reduce the risk of picking up the airborne signal.