C-SCOPE SG-V Instruction Manual Page 51

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 50
C.Scope Locator:
Depth Measurement Checks (DXL and MXL Locators only)
Depth Measurement
An area clear of services and metal structures should be
chosen (beware of reinforced concrete car parks). A search
with the C.Scope Locator in all 4 modes will help confirm
the absence of other services. An insulated cable or wire
over twenty metres long (not supplied) is laid out on the
ground surface and the far end connected to a ground
stake and earthed. The near end is connected to the red
Direct Connection Lead.
The black Earth Lead should be laid at right angles to
the 20 metre cable and earthed at the far end with
the Earth Stake. The plug should be inserted in the
connector on the Generator/ Transmitter.
The Generator/ Transmitter is turned on to the lowest
Output Power Level, 33kHz (MXT Transmitter only) and
Continuous Mode. The Locator should then be held
vertically above the longer cable, approximately
midway along it.
The depth can then be measured. It is best to make
a few readings at different depths. Beware - metal step
ladders affect the accuracy!
(MXL Locators only:
This procedure can then be repeated using 8kHz
and 640/512Hz).
51
NOTE These checks cannot be used to confirm the equipment is performing to the specifications
on page 53.